The factory default combination for Sargent and Greenleaf electronic locks are set to 1 2 3 4 5 6.
Please make sure that you have the door open and the handle turned in the lock position. Once you have performed the operation test the new combination 3 times before closing the door.

2 2 * (or 3 3 *) YOUR OLD CODE # (5 beeps ) NEW CODE # (3 beeps ) NEW CODE # (3 beeps )

EX

Applicable to:
Titan Pivot bolt (2006) and Direct Drive (2007)
Spartan Pivot bolt (1006) and Direct Drive (1007)
MPP (1004) Spin Blocker

Related Products